Call us at 713.747.4110 or email info@gabbertcompany.com
   
       Commercial WallMaster  
  PDF Sales Brochure
  PDF Warranty
Kuhl
 

Full Range of Model Specifications.

WallMaster comes in a range of sizes and capacities. Click on the model number for detailed installation information. Take a look.


WallMaster

Model Cooling
Btu
Heating
Btu
EER CEER Volts Rated ENERGY STAR® Qualified Chassis
Height
Chassis
Width
Chassis
Depth
WS08D10 8000 n/a n/a 10.2 115v No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 115
      Cooling Amps: 6.4
      Heating Amps: n/a
   Air Circulation: 250 cubic feet per minute
   Est. Yearly Operating Costs: n/a
   Moisture Removal: 1.8 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a
 

WS10D10 9700 n/a n/a 9.7 115v No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 115
      Cooling Amps: 8
      Heating Amps: n/a
   Air Circulation: 260 cubic feet per minute
   Est. Yearly Operating Costs: $89
   Moisture Removal: 2.4 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a
 

WS10D30 10000/
9800
n/a n/a 9.7/
9.7
230/
208v
No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 4.5/4.9
      Heating Amps: n/a
   Air Circulation: 260 cubic feet per minute
   Est. Yearly Operating Costs: $92
   Moisture Removal: 1.5 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a
 

WS12D10 12000 n/a n/a 9.7 115v No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 115
      Cooling Amps: 10.8
      Heating Amps: n/a
   Air Circulation: 295 cubic feet per minute
   Est. Yearly Operating Costs: $110
   Moisture Removal: n/a
   Net Weight: n/a
   Shipping Weight: n/a
 

WS12D30 12000/
11700
n/a n/a 9.7/
9.7
230/
208v
No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 5.5/5.8
      Heating Amps: n/a
   Air Circulation: 290 cubic feet per minute
   Est. Yearly Operating Costs: $110
   Moisture Removal: n/a
   Net Weight: n/a
   Shipping Weight: n/a
 

WS15D30 14500/
14000
n/a n/a 9.3/
9.3
230/
208v
No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 7/7.6
      Heating Amps: n/a
   Air Circulation: 290 cubic feet per minute
   Est. Yearly Operating Costs: $140
   Moisture Removal: 4.8 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a
 


WallMaster + Heat Pump

Model Cooling
Btu
Heating
Btu
EER CEER Volts Rated ENERGY STAR® Qualified Chassis
Height
Chassis
Width
Chassis
Depth
WY09D33 8700/
8500
6500/
6400
8/
8.2
9.3/
9.3
230/
208v
No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 4.6/4.6
      Heating Amps: 4.3/4.4
   Air Circulation: 260 cubic feet per minute
   Est. Yearly Operating Costs: n/a
   Moisture Removal: 2.6 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a
 

WY12D33 11300/
11000
8900/
8700
8/
8
9.3/
9.3
230/
208v
No 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 5.5/5.6
      Heating Amps: 5/5.3
   Air Circulation: 275 cubic feet per minute
   Est. Yearly Operating Costs: $109
   Moisture Removal: 3.4 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a
 


WallMaster + Electric Heat

Model Cooling
Btu
Heating
Btu
EER CEER Volts Rated ENERGY STAR® Qualified Chassis
Height
Chassis
Width
Chassis
Depth
WE10D33 10000/
9800
11000/
9100
n/a 9.7/
9.7
230/
208v
n/a 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 4.5/4.9
      Heating Amps: 16/14.7
   Air Circulation: 260 cubic feet per minute
   Est. Yearly Operating Costs: $92
   Moisture Removal: 1.5 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a
 

WE12D33 12000/
11700
11000/
9100
n/a 9.7/
9.7
230/
208v
n/a 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 5.5/5.8
      Heating Amps: 16/14.7
   Air Circulation: 290 cubic feet per minute
   Est. Yearly Operating Costs: $110
   Moisture Removal: n/a
   Net Weight: n/a
   Shipping Weight: n/a
 

WE15D33 14500/
14000
11000/
9100
n/a 9.3/
9.3
230/
208v
n/a 15 3/4" 26 1/2" 21"

 

Unit Dimensions
   Height: 15 3/4"
   Width: 26 1/2"
   Depth: 21"

Window Dimensions
   Height: 15 3/4"
   Width: n/a
   Depth: n/a

Additional Measurement Information
   Depth to Louvers: 15 5/16"
   Sleeve Size: WSE
Detailed Electrical Information
      Voltage: 230/208
      Cooling Amps: 7/7.6
      Heating Amps: 16/14.7
   Air Circulation: 290 cubic feet per minute
   Est. Yearly Operating Costs: $140
   Moisture Removal: 4.8 pints per hour
   Net Weight: n/a
   Shipping Weight: n/a